FIRE PROTECTION CLOSURE
Self-closing fire doors
At neuform, we offer you single-leaf or double-leaf self-closing fire doors. To select the right solution for you, fire-resistance ratings must be taken into account. They specify the length of time the door is able to withstand a fire – i.e. how long the door must provide thermal insulation or prevent the spread of flames, and yet still be able to open. neuform fire doors are available with the fire resistance ratings T30 (30 minutes’ resistance) and T90, and F30 and F90 for fire-protective glazing. International fire resistance ratings are specified as EI30 or EI90.
Whatever their precise design or configuration, fire doors are only at their most effective when the door leaf, frame, seals, hinges and lock, and above all the door closer – with or without a hold-open device – are all carefully matched. Because it takes the right combination of seamlessly integrated elements to make the difference when it truly counts: in the event of an emergency.
PLANNING AIDS
DIN 4102 – Fire behaviour of building materials and building components
DIN EN 16034 – European product standard
DIN EN 1634 – European testing standard
DIN EN 13501-2 – Classification
Duration | DIN 4102-5 - Class | DIN EN 13501-2 - Class | Attribute |
---|---|---|---|
30 min | T 30 | EI 2 30-C5 | 30-minute fire rating |
60 min | T 60 | EI 2 60-C5 | 60-minute fire rating |
90 min | T 90 | EI 2 90-C5 | 90-minute fire rating |
BEST MATCH
FIRE PROTECTIVE GLAZING
A defence against fire, smoke and heat
In addition to other fire-resistant elements, such as self-closing doors, neuform fire-protective glazing makes a key contribution to people’s safety inside buildings.
Fire-protective glazing supports fire compartmentalisation, and comprises a single or multiple transparent elements. Depending on its fire resistance rating, it prevents the spread of flame and impedes heat radiation. The ratings, e.g. F30 and F90 indicate the duration of fire resistance in minutes. Each fire-protective glazing element is made of several glass panes. In the event of a fire, the pane facing the fire shatters and a heat shield forms.
As with doors, the ideal interaction of components is important to ensure a safe environment and to comply with statutory safety requirements.
It is important to note: doors and glazing can only be combined when they share the same fire resistance rating (F30 / T30 or F90 / T90).
PLANNING AIDS
Model building code (basic) - main tasks:
- Prevent fire, prevent the spread of fire and smoke, enable rescue and effective extinguishing operations.
- Prevent the passage of heat radiation
State building code - based on this, regulates state-specifically
DIN 4102 -13 - Fire behaviour of building materials and building components
abZ - general building approval - required for fire-resistant glazing made of wood
aBG - general type approval - for construction products (infill elements) for fire resistant glazings
EN 1634, DIN EN 1361-1 - European testing standard
DIN 18008-4 - Additional requirements for fall arrest glazing - Rules for dimensioning and construction
Duration | DIN 4102-13 - Class | Attribute |
---|---|---|
30 min | F 30 | 30-minute fire rating |
60 min | F 60 | 60-minute fire rating |
90 min | F 90 | 90-minute fire rating |
BEST MATCH
DIMENSIONS
Fire door: dimensions, single-leaf door
Duration (Min) | Model | Leaf thickness (mm) | Clear frame passage – max. w x h (mm) | Frame installation dimension – max. w x h (mm) |
---|---|---|---|---|
30 | HT 50 - T30(RS) - BASIC | 50 | 1250 x 2593 | 3500 x 3750 |
30 | HT 70 - T30(RS) - EXTRA | 70 | 1561 x 3468 | 3500 x 3875 |
30 | HT 70 - T30(RS) - SONIC | 70 | 1311 x 2843 | 3500 x 3875 |
30 | RT 70 - T30(RS) - FRAMIC | 70 | 1311 x 2843 | 3500 x 3875 |
90 | HT 70 - T90(RS) - SUPRA | 70 | 1311 x 2843 | 3500 x 3875 |
Fire door: dimensions, double-leaf door
Duration(Min) | Model | Leaf thickness (mm) | Clear frame passage – max. w x h (mm) | Frame installation dimension – max. w x h (mm) |
---|---|---|---|---|
30 | HT 50 - T30(RS) - BASIC | 50 | 2544 x 2593 | 4500 x 3750 |
30 | HT 70 - T30(RS) - EXTRA | 70 | 3156 x 3468 | 4500 x 3875 |
30 | HT 70 - T30(RS) - SONIC | 70 | 2686 x 2843 | 4500 x 3875 |
30 | RT 70 - T30(RS) - FRAMIC | 70 | 2686 x 2843 | 4500 x 3875 |
90 | HT 70 - T90(RS) - SUPRA | 70 | 2578 x 2843 | 4500 x 3875 |
Fire-protective glazing: dimensions
Class | Wall type | Width (mm) | Height (mm) |
---|---|---|---|
F 30 | Solid wall | Unlimited | 5000 |
F 30 | Partition | 6000 | 4000 |
F 90 | Solid wall | Unlimited | 3500 |
F 90 | Partition | Unlimited | 3500 |