Stadtarchiv Köln Foto: Thomas Möller
Rathaus Marbach Foto: Thomas Möller
Kinderhaus Pezzettino Kernen Foto: Markus Guhl

Fixed glazing

High-quality glazed walls: Stable construction and individual design options

neuformtür glazed walls are a stable mullion and transom construction consisting of solid glulam including the appropriate surface coating. Fastening the panes or panels on one side using cover profiles not only offers visual advantages, but also enables user-friendly installation.

The sharp-edged structure of this design sets it apart from conventional rounded DIY store quality at the highest level. To underline this, neuformtür uses a 1.2 mm thick-cut veneer for wooden surfaces. Thanks to an innovative modular system, various connections can be created in the form of couplings of various stiles or connecting stiles according to customer requirements. This not only has the advantage of separating huge areas, but also of dividing rooms as required using corner joints. The maximum possible width in DIN partition walls is 6 meters.

At neuformtür, there are numerous design options in terms of dimensions, design and glass type. We will of course be happy to advise you on our products.

Klinik Mainz Foto: Stefan Marquardt
Kita Ditzingen Foto: Stefan J. Müller
Murr Elektronik Oppenweiler Foto: Thomas Möller

FIRE-RESISTANT GLAZING

700x635

Festverglasung in der Gemeinschaftsschule Ammerbuch Flur und Blick ins Grüne

The multifunctional glazing consists of several panes of glass with silicate layers in between. In the event of a fire, the outer glass pane facing the fire shatters to allow the fire protection layers to foam up. This activates the so-called fire protection formers. F (fire) glazing not only prevents the spread of fire and smoke, but also the passage of heat radiation.

F glazing becomes opaque when exposed to fire and forms a heat shield - it behaves like walls in terms of fire protection. F glazing requires a general approval from the German Institute for Building Technology (DIBt). F glazing is impermeable to radiation and is tested and classified like walls in accordance with the test standard. This means that F-glazing can be used without restriction as room-enclosing walls or as partial areas within them in accordance with the general approval.

It should first be noted that doors and glazing can only be combined if they have the same fire resistance class.

SMOKE CONTROL GLAZING

700x635

Festverglasung in den Inklusionswerkstätten Ligue HCM Capellen

There is currently no separate test standard for smoke control glazing. Fixed glazing is considered smoke-tight if the following requirements are met:

  • use of suitable smoke protection safety glass,
  • use of permanently elastic sealants, e.g. silicone,
  • sealing of construction joints,
  • installation in accordance with the manufacturer's instructions.

Smoke control glazing is not labeled by the building authorities. The combination of smoke protection doors with smoke protection glazing must be verified by the manufacturer from a permanent functional point of view.

AREAS OF APPLICATION

700x635

Festverglasung im Flur im Burggymnasium Schorndorf

The room or area separation of such fire-resistant glazing is recommended for new builds, extensions or renovations in public buildings, such as:

  • Offices:
    area and corridor separation with high light incidence,
    access to executive areas
     
  • Hospitals:
    separation of operating theaters,
    nurses' area / waiting room for patients
     
  • Schools:
    building connections,
    access to the assembly hall,
    classrooms with high light flooding
     
  • Hotels:
    access to wellness area,
    restaurant
     
  • Airports:
    connection between terminals and gates,
    separation of VIP lounges
     
  • Kindergartens:
    gymnasiums with screens for supervisors

ADVANTAGES

700x635

Festverglasung in der Turnhalle in der Integrierten Gesamtschule Riedberg
  • maximum incidence of light due to increased proportion of glass surfaces, high transparency

  • narrow profile face width of 60 mm

  • integration of T30 elements to match the rest of the building complex

  • all doors from a single source - neuform covers all multifunctional requirements for F30 glazing such as fire, smoke, sound and burglary protection, so all doors in a building project have the same appearance and quality

  • flexibility when widening and shortening on site (small changes or adjustments to the wall can be made on site)

  • special designs (according to customer requirements) can be realized within the scope of type approval and production possibilities

  • wall connection strips/rungs freely selectable in dimensions and shape

  • room partitioning in maximum dimensions (length x width), large format possible in conjunction with XXL elements, no impairment of the protective function

  • partitioning and arrangement of the glass wall as desired while adhering to the glass panel dimensions

  • huge selection of surfaces (veneers, HPL coatings and RAL/NCS paint finish)

  • wood as a natural product (visual warmth, feel-good atmosphere)

BEST MATCH